61阅读

网易密保卡更换-HPSuperdome定位网卡位置并更换

发布时间:2018-03-02 所属栏目:小米4后置摄像头更换

一 : HPSuperdome定位网卡位置并更换

HP Superdome定位网卡并更换网卡(www.61k.com)

假定HP superdome 有三个分区

分区0 cell 0 cell 3

分区1 cell 2

分区2 cell1

如何定位 lan1 网卡(0/0/8/1/0

#ioscan -funClan

Class I H/W Path Driver S/W State H/W Type Description

=====================================================================

lan 0 0/0/1/1/0 iether CLAIMED INTERFACE HP AD331-60001 PCI/PCI-X 1000Base-T Adapter

lan 10/0/8/1/0iether CLAIMED INTERFACE HP AD332-60001 PCI/PCI-X 1000Base-SXAdapter

lan 2 0/0/9/1/0 iether CLAIMED INTERFACE HP AD332-60001 PCI/PCI-X 1000Base-SXAdapter

lan 3 0/0/12/1/0 iether CLAIMED INTERFACE HP AD331-60001 PCI/PCI-X 1000Base-T Adapter

lan 4 3/0/1/1/0 iether CLAIMED INTERFACE HP AD332-60001 PCI/PCI-X 1000Base-SXAdapter

lan 5 3/0/8/1/0 iether CLAIMED INTERFACE HP AD332-60001 PCI/PCI-X 1000Base-SXAdapter

lan 6 3/0/9/1/0 iether CLAIMED INTERFACE HP AD332-60001 PCI/PCI-X 1000Base-SXAdapter

lan 7 3/0/12/1/0 iether CLAIMED INTERFACE HP AD332-60001 PCI/PCI-X 1000Base-SXAdapter

#ioscan -funCfc

Class I H/W Path Driver S/W State H/W Type Description

======================================================================

fc 0 0/0/4/0/0/0/0 fclp CLAIMED INTERFACE HP AD299-60001 4Gb PCIe 1-port FibreChannel Adapter

/dev/fclp0

fc 1 0/0/5/0/0/0/0 fclp CLAIMED INTERFACE HP AD299-60001 4Gb PCIe 1-port Fibre ChannelAdapter

/dev/fclp1

fc 2 3/0/4/0/0/0/0 fclp CLAIMED INTERFACE HP AD299-60001 4Gb PCIe 1-port FibreChannel Adapter

/dev/fclp2

fc 3 3/0/5/0/0/0/0 fclp CLAIMED INTERFACE HP AD299-60001 4Gb PCIe 1-port FibreChannel Adapter

/dev/fclp3

#olrad -q

Driver(s)

Capable

Slot Path Bus Max Spd Pwr Occu Susp OLAR OLD Max Mode

Num Spd Mode

0-0-3-0 3/0/0/1 12288 133 133 Off No N/A N/A N/A PCI-X PCI-X

0-0-3-1 3/0/1/1 12544 133 133 On Yes No Yes Yes PCI-X PCI-X

0-0-3-8 3/0/12/1 14592 133 133 On Yes No Yes Yes PCI-X PCI-X

0-0-3-9 3/0/10/1 14336 133 133 On Yes No Yes Yes PCI-X PCI-X

0-0-3-10 3/0/9/1 14080 133 133 On Yes No Yes Yes PCI-X PCI-X

0-0-3-11 3/0/8/1 13824 133 133 On Yes No Yes Yes PCI-X PCI-X

0-1-3-0 0/0/0/1 0 133 133 Off No N/A N/A N/A PCI-X PCI-X

0-1-3-1 0/0/1/1 256 133 133 On Yes No Yes Yes PCI-X PCI-X

0-1-3-8 0/0/12/1 2304 133 133 On Yes No Yes Yes PCI-X PCI-X

0-1-3-9 0/0/10/1 2048 133 133 On Yes No Yes Yes PCI-X PCI-X

0-1-3-10 0/0/9/1 1792 133 133 On Yes No Yes Yes PCI-X PCI-X

0-1-3-11 0/0/8/11536 133 133 On Yes No Yes Yes PCI-X PCI-X

PCI-Express SlotsInformation

-----------------------------

Driver(s)

Capable

Slot Path Link Max Max Link Pwr Occu Susp OLAR OLD Mode

Spd Link Link Width

Spd Width

0-0-3-2 3/0/2/0/0/0 2.5 2.5 x8 x8 On Yes No Yes Yes PCIe

0-0-3-3 3/0/4/0/0/0 2.5 2.5 x8 x4 On Yes No Yes Yes PCIe

0-0-3-4 3/0/5/0/0/0 2.5 2.5 x8 x4 On Yes No Yes Yes PCIe

0-0-3-5 3/0/6/0/0/0 2.5 2.5 x8 x8 On Yes No Yes Yes PCIe

0-0-3-6 3/0/14/0/0/0 2.5 2.5 x8 x8 Off No N/A N/A N/A PCIe

0-0-3-7 3/0/13/0/0/0 2.5 2.5 x8 x8 Off No N/A N/A N/A PCIe

0-1-3-2 0/0/2/0/0/0 2.5 2.5 x8 x8 On Yes No Yes Yes PCIe

0-1-3-3 0/0/4/0/0/0 2.5 2.5 x8 x4 On Yes No Yes Yes PCIe

0-1-3-4 0/0/5/0/0/0 2.5 2.5 x8 x4 On Yes No Yes Yes PCIe

0-1-3-5 0/0/6/0/0/0 2.5 2.5 x8 x8 On Yes No Yes Yes PCIe

0-1-3-6 0/0/14/0/0/0 2.5 2.5 x8 x8 Off No N/A N/A N/A PCIe

0-1-3-7 0/0/13/0/0/0 2.5 2.5 x8 x8 Off No N/A N/A N/A PCIe

#parstatus // 查看分区的情况,及分区的当前状态。

Note: No action specified. Defaultbehavior is display all.

[Complex]

Complex Name : Complex 01

Complex Capacity

Compute Cabinet (4 cell capable) : 1

Active MP Location : cabinet 0

Original Product Name : superdome server SD16B

Original Serial Number : SGH492xxxx

Current Product Order Number : A9xxxx

OEM Manufacturer :

Complex Profile Revision : 1.0

The total number of partitions present : 3

GSM sharing : Disabled Complex-wide

[Cabinet]

Cabinet I/O Bulk Power Backplane

Blowers Fans Supplies Power Boards

OK/ OK/ OK/ OK/

Cab Failed/ Failed/ Failed/ Failed/

Num Cabinet Type N Status N Status N Status N Status MP

=== ============ ========= ========= ========== ============ ======

0 4 cell slot 4/0/N+ 5/0/N+ 4/0/N+ 2/0/N+ Active

Notes: N+ = There are one or more spareitems (fans/power supplies).

N = The number of items meets butdoes not exceed the need.

N- = There are insufficient items to meet the need.

? = The adequacy of the coolingsystem/power supplies is unknown.

HO = Housekeeping only; The power is in a standby state.

NA = Not Applicable.

[Cell]

CPU Memory Use

OK/ (GB) Core On

扩展:superdome 背板 更换 / hp superdome / hp superdome维护手册

Hardware Actual Deconf/ OK/ Cell Next Par

Location Usage Max Deconf Connected To Capable BootNum

========== ============ ======= ============================ ======= ==== ===

cab0,cell0 Active Core 8/0/8 48.0/0.0 cab0,bay1,chassis3 yes yes 0

cab0,cell1 Active Core 8/0/8 48.0/0.0 cab0,bay1,chassis1 yes yes 2

cab0,cell2 Active Core 8/0/8 48.0/0.0 cab0,bay0,chassis1 yes yes 1

cab0,cell3 Active Base 8/0/8 48.0/0.0 cab0,bay0,chassis3 yes yes 0

cab0,cell4 Absent * - - - - - -

cab0,cell5 Absent * - - - - - -

cab0,cell6 Absent * - - - - - -

cab0,cell7 Absent * - - - - - -

注释:cab0 就是superdome 的 32 路的一个大柜子 ,当superdome 是 64 路时,则 有两个柜子。就会出现 cab1,当前cab0上只有 4块 cell 板---cell 0-cell3

Notes: * = Cellhas no interleaved memory.

[Chassis]

CoreConnected Par

Hardware Location Usage IO To Num

=================== ============ ============== ===

cab0,bay0,chassis0 Absent - - -

cab0,bay0,chassis1 Active - cab0,cell2 1

cab0,bay0,chassis2 Absent - - -

cab0,bay0,chassis3 Active - cab0,cell3 0

cab0,bay1,chassis0 Absent - - -

cab0,bay1,chassis1 Active - cab0,cell1 2

cab0,bay1,chassis2 Absent - - -

cab0,bay1,chassis3 Active - cab0,cell0 0

-----------------注释:cab0 里面包含 bay0 和 bay1

[Partition]

Par # of # of I/O

Num Status Cells Chassis Core cell Partition Name (first 30 chars)

=== ============ ===== ======== =========================================

0 Active 2 2 cab0,cell0 Partition 0 - UX

1 Active 1 1 cab0,cell2 Partition 1 - UX

2 Active 1 1 cab0,cell1 Partition 2 - UX

[Partition - HyperThread]

Par Num Hyperthreading Enabled Hyperthreading Active

======= ====================== =====================

0 yes yes

1 yes yes

2 yes yes

------------------------------------------------------------------------------------------------

注意:插槽 ID 的编号视平台而定。在低级平台上,插槽 ID 仅包含插槽编号。在其他所有平台中 (包括Superdome),插槽 ID 的格式为:Cabinet#-Bay#-Chassis#-Slot#

Lan1 的slot号为:0-1-3-11

即: Cabinet 为0, Bay#为1IOChasis 3 的slot 11位置(其实知道IOClasis就行了)

打开SuperDome前门(能看见电源线的一边是后门),IO 笼子上一般有IOChasis的标号。找到IOChasis3,再找到slot 11,就找到了该网卡。

小技巧: 可以使用olrad &ndash;I ATTN <solt ID> 来让相应的solt警示灯闪烁

-----------------------------------------------------------------------

olrad 命令提供在线新增,替换和删除I/0卡的能力

olrad 命令会在执行任何 OL*作业之前执行系统的关键资源分析(CRA),确保系统的新增,替换或删除PCI 卡后,不会留在不一致的状态

常用参数:

-q 显示系统中所有可能使用OL* 的插槽的状态,具有相同汇流排编号的插槽视为公用插槽

-I flag 插槽ID 控制注意LED的状态。此flag 选项的有效值 为 ATTN 和 OFF 。对应插槽的注意LED会根据flag 值设为适当的状态。ATTN 会将LED 转为 闪烁。flag 不区分大小写

-C 插槽ID 在指定的插槽ID 上执行CRA并显示结果。这样会检查所有与指定插槽相关受影响硬件路径的关键资源。它会分析档案系统,容量,处理程序,网络作业,置换(swap)和dump,并产生受影响资源的报告。

--------- 实例一:判断插槽状态-------------

#olrad -q

--------- 实例二:执行CRA-------------

#olrad -C 插槽ID

CRA 严重性登机

1、CRA returnSUCCESS 无使用中的受影响资源

2、CRA returnWARNINGS 受影响装置上的资源使用中,但均不被视为关键资源

3、CRA returnDATA_CRITICAL 执行作业时可能会遗失资料,因此请考虑后再继续执行

4、CRA returnSYS_CRITICAL 作业可能导致系统关机

5、CRA return ERROR遇到内 CRA 错误

--------- 新增卡 的实施方法 ---

1、完成准备动作

#olrad -q

#olrad -C 插槽id

2、准备新增

#olrad -a 插槽ID //进行 CRA 检查,并且停止驱动,关闭卡的电源

3、将卡安装到插槽中

4、输入一下命令

#olrad -A 插槽id //插槽加电,并重新加载相关驱动

5、验证是否成功

#olrad -q 插槽id

---------- 更换坏卡-----------

1、完成准备动作

#olrad -q

#olrad -C 插槽id

2、准备替换

#olrad -r 插槽id

3、替换卡(注意:新卡和旧卡必须使用相同的驱动程序)

4、输入一下命令

#olrad -R 插槽id

5、验证 作业是否成功

#olrad -q

---------- 删除 卡---------------

1、完成准备动作

#olrad -q

#olrad -C 插槽id

2、准备删除

#olrad -d 插槽id //删除卡,首先进行 CRA检测,删除驱动实例,关闭电源

3、移除卡

4、输入一下命令

#olrad -D 插槽id //删除卡,一般在olrad 命令之后,用于完成卡的删除

5、验证

olrad -q

------------- 将注意灯 转为闪烁或 熄灭 --------

#olrad -I ATTN 插槽id

#olrad -I off 插槽id

扩展:superdome 背板 更换 / hp superdome / hp superdome维护手册

二 : 关于密保卡帮定密保卡后,官网会提示建议更换时间,是不是到时候就必

关于密保卡

帮定密保卡后,官网会提示建议更换时间,是不是到时候就必须换卡了,还是只表示建议,换不换都可以,还有,平时如果经常在家上,且一周只上1,2次,需要常换卡吗


每周一两次的话,那你3个月换一次卡吧,如果家里机没病毒的话一辈子都不用换了,还有密保卡可以无限使用,直到你换卡为止

三 : 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条在雨天可以为驾驶者清除雨水,保障视野范围的汽车工具,不要小看这个不起眼的设备,说起来可是与您的安全有很大的联系。(www.61k.com]因此日常保养项目中也不可省了它,关于它的使用、更换、保养都是很重要的。

雨刷胶条的使用好坏关系到更换时间的长短,而保养则是使用过程必不可少的操作,三者互相联系,缺一不可。

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条的使用:

使用前后都要注意,使用前检查雨刷周围是否有赃物,有的话,及时处理干净,尤其是大的沙石,并将挡风玻璃表面擦洗干净,使用后也要记得清洗,这是很多朋友容易忽视的问题,但是此项操作一定不要省去。

雨刷胶条的更换:

雨刷胶条属于不耐型的用品,这就是很多朋友反映没怎么使用就坏的原因,使用久了难免会出现故障需要更换,一般情况下一年需要更换一次,更换非常的简单,不过需要重视一项问题:原厂的雨刷两头的盖帽非常紧,一定要小心以防您的身体受到影响。

一定要将雨刷支架轻轻地放到风挡玻璃上,千万不要支起来,如果支架弹到风挡玻璃上,那可得更换风挡玻璃了。

雨刷胶条的保养:

要想雨刷胶条使用的更久,保养工作就要做到位,保养工作的到位不到位,直接关系到雨刷胶条使用时间的长短。因此,一定要注重保养技巧。

使用雨刷胶条是的速度要适中,有些朋友为了快速的清除雨水,使用时时快时慢,这是非常错误的做法,一定要注意使用频率的快慢。

雨刷胶条很容易出现老化的现象,因此平时要清洗时要注意清洁剂的浓度问题,浓度高的对于雨刷胶条来说是加快了老化,缩短了使用寿命,最好选择专门用于清洗汽车的清洁剂,效果会更好。

避免让雨刷和玻璃长时间接触,记得在每次停车之后把雨刷竖起来,尽量避免雨刷一直和玻璃贴合,这个小动作也是延长寿命的秘诀特别是在烈日高照的夏天,紧贴住玻璃的橡胶条是很容易因为高温,而造成变形或失去弹性的。

雨刷胶条使用与更换和保养,三者缺一不可,一定要关注它们,这不仅可以有效的保护雨刷胶条的寿命,同时也是您安全车行的保障。

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

雨刷胶条 雨刷胶条使用更换保养!逸卡雨刷,全网销量第一!

本文标题:网易密保卡更换-HPSuperdome定位网卡位置并更换
本文地址: http://www.61k.com/1131498.html

61阅读| 精彩专题| 最新文章| 热门文章| 苏ICP备13036349号-1